BEST GROUP
SERVICES

Mud Logging Unit:

The Mud logging unit is a proven design developed as the result of more than 10 years experience with unit operations, engineering and maintenance. Every feature of the mud logging unit aims to provide a rugged, efficient and safe working environment.

Unit Features:

  • DNV certification for Zone I & II onshore and offshore work areas.
  • Rugged skid mounted steel construction.
  • Twin Air conditioners.
  • 25KVA Transformer with selection of main power voltage.
  • Two 3 KVA UPS´s backup.
  • Pressurized and explosion proof with automatic power shutdown.
  • Intrinsically safe electrical system.
  • Unit combustible gas alarm.
  • Unit H2S gas alarm.
  • Unit emergency lighting system.
  • Escape hatch.
  • Large storage space.

DAPS System:

DAPS is a comprehensive hardware and software system primarily intended for Mud Logging. The system consists of an array of sensors installed on a drilling rig, a data acquisition subsystem and real-time software processing. DAPS is sometimes deployed as a simple mud pit level monitoring system but is flexible enough to scale up to a full rig-instrumentation and mud logging package.

         DAPS Functions:

  • Acquire data from rig sensors and gas instruments in real-time.
  • Process the data and update derived channel data.
  • Store data in server database based on time and depth intervals.
  • Allow connections from client computers for remote workstations.
  • Provide database graphical playback.
  • Update and control external alarms.
  • WITS data import/export

    DAPS System Components:

  • DAPS Box – Ethernet 100Mbps data acquisition and sensor signal termination.
  • DAPS online SERVER.
  • DAPS offline SERVER.
  • DAPS logger SERVER.
  • DAPS gas system.
  • Rig sensors.
  • Offline log and report printer.
  • Online uninterruptable power supply (UPS).